SMART-S 825


SMART-S 825 Model Sterilizer

Steam Sterilizer with automatic sliding door and touchscreen control unit

   
Chamber volume (StE) : 12
Model : Double door
Door system : Sliding door
Chamber volume (lt) : 825
 
 

Specifications:

GENERAL SPECIFICATIONS:

• Material: Vessel, Jacket, Generator
• Exterior body : AISI 304
• 4 polyamid vehicle for easy transporting

STANDARD PROGRAMS:

• 121 ºC Rubber
• 125 ºC Rubber
• 134 ºC Instrument
• 134 ºC Textile
• Bowie-Dick Test 
• Leakage test 
• Optional programs

CONTROL UNIT:

• 7" colour touchscreen display
• Full automatic with microprocessor 
• Second microprocessor control system (generator pressure, water level, jacket pressure, air pressure ext.) 
• MemoTrans validation system (optional) 

GENERATOR:

Generator information for each product are shown in the "Product Specifications" document.

DOOR SYSTEM:

• Automatic sliding door 
• Manual system for urgent cases 
• Automatic open-close for sliding door systems 
• Door safety locking 
• Door closing safety

ALARMS:

• Visual, written and audible warning monitoring 
• Pressure error (vacuum), steam error (temperature), electric failure (audible and visual warning), low water level, door alarm 
• If heat is lower than 1 ºC from setting value, alarm is given and sterilization starts anew. 
• During electric cut-off if parameters are appropriate sterilization continues from proper position, if requested, if stopes.

POWER SUPPLY:

• 220/380 VAC - 50 Hz (+)

PRINTER:

• Thermal technology (40 colon) 
• Cartridge dot strike (optional) 
• Written informations : 
- Date and clock 
- Sterilization no, name and counter 
- Preheating time and number 
- Prevacuum time and number 
- Sterilization temperature and time 
- Drying time, sterilization phases pressure and temperature values for moment instant. 
- Error conditions and date, clock informations 
- System barring stopping or cutting sterilization date, clock informations 
- Date, clock and total time informations completing sterilization time

MONITORING PARAMETERS:

• Program name and number 
• Sterilization phases 
• Generator water level 
• Vessel pressure and temperature, 2.sensors (optional) 
• Jacket, generator and seal pressures (optional) 
• Jacket and generator temperatures (optional) 
• Total sterilization time and remaining time 
• Sterilization pressure and temperature values 
• Sterilization counter 
• Real time and date 
• Errors and error occasions

STEAM INSTALLATION:

• Material : AISI 304, brass and copper (Cu) 
• Pneumatic solonoid valves 
• Pure steam system (CE) 
• Calibrated manometers for vessel , jacket, generator and **seal 
• 0.2 µm